SITEC – Soluciones e Integraciones Tecnologicas

CLIMATIC CHAMBER

This equipment or facilities used in laboratories, designed to simulate controlled conditions of temperature and relative humidity inside and carry out studies or test with which to verify the behavior, durability and quality of products.

Temperature and humidity chambers are available as standard products in a wide variety of sies. The chambers are used for steady-state stability test, basic temperature cycling and accelerated stress test.

Z-PLUS TEMPERATURE AND HUMIDITY CHAMBER

MICROCLIMA® 3

Capacity: 8, 16, 32, 44, 64, 80 o 96 ft3.

Temperature range: 

  • Single Stage: -34°C a +190°C 

  • Tundra®: -45°C a +190°C 

  • Cascade: -70°C a +190°C 

Humidity range:

  • 10% a 98% RH

  • 5% a 98% RH (Optional)

Model MC(H)-3 

Capacity: 3 ft^3

Temperature range:

  • -68°C a +190°C (-90°F a +375°F)

Humidity range (Optional):

  • 10% a 95% RH

MICROCLIMA® BENCHTOP

REMOTE CONDITIONERS

Model MCB(H)-1.2

Capacity:

1.2 ft^3

Temperature range:

  • Single Stage: -30°C a +190°C

  • Cascade: -68°C a +190°C

Humidity range (Optional)

  • 10% a 95% RH

Model RC(H),  ZPRC(H)

Capacity:

  •  8, 16, 32, 44 y 64 ft^3

  • Custom sizes available

Temperature range:

  • Single Stage: -34°C a 190°C

  • Tundra®: -45°C a 190°C

  • Cascade: -70°C a 190°C

Humidity range (Optional):

  • 10% a 95% RH

Bower capacity:

  • 300 a 800 CFM

PharmaEvent Stability Chambers

MODEL 280 280 600 1300 2000
Capacity
10 cu. ft. (280 L)
21 cu. ft. (280 L)
46 cu. ft. (280 L)
71 cu. ft. (280 L)
Temperature range
+2°C to +70°C
Humidity range (optional)
20% to 90% RH
Temperature control (On time)
±0.1 to 0.2°C
Uniform temperature (On space)
±0.3 to ±1°C
Humidity control (In Time)
±0.2 to ±1%
Uniform Humidity (On space)
±0.5 to ±2%
Grids number
2
6
12
18

THERMAL SHOCK CHAMBER

Compact thermal shock chamber VTS

Compact thermal shock chambers

  • VTS-1 Model
    Capacity: 1 ft^3

    Temperature range:

    Cold/hot chamber -75°C to +190°C

    Hot chamber 50°C to +210°C

    Maximum product load
    20 lbs. (9 kg)

  • VTS-3 Model
    Capacity: 3 ft^3
    Temperature range:
    Hot/cold chamber -75°C to +190°C
    Hot chamber 50°C to +210°C
    maximum product load 25 lbs. (11 kg)

VTS Thermal shock chamber

VTS Thermal shock chamber

  • VTS-9 model
    Capacity: 9 cu. ft. (255L) CSZ also we can custom design larger sizes to meet your testing needs.
    Temperature range:
    Hot chamber 115°C a +210°C (239°F a +410°F)
    Cold/hot chamber -75°C to +190°C (-103°F to +375°F)
    Sizes; 25” x 25” x 25” (63.5cm x 63.5cm x 63.5cm)

Horizontal thermal shock chambers

Horizontal thermal shock chamber

Load capacities
16 and 27 cu. ft. (450 to 765 L) 
Custom capacity available
Temperature Range
- Hot Zone: 71°C to +210°C (160°F to +410°F)
- Cold/hot zone: -75°C to +190°C (-103°F to +375°F)

Liquid Thermal Shock Chambers

Liquid Thermal Shock Chambers



TSB model
Load Capacities
2 lbs (.9 kg) and 5 lbs (2.3 kg) of ICs
available.


Temperature range:

  • Hot bath: Ambient to +160°C (+320°F)
  • Cold Bath: Ambient to -75°C (-103°F)

TEMPERATURE & VIBRATION CHAMBERS

Benchtop Vibration Table

Benchtop Vibration Table

TCB model 
Workspace: 41cm x 41cm x 25cm
Exterior dimensions: 84cm x 79cm x 58cm
Table base: 56cm x 64cm x 30cm

Temperature range: (When used with environmental chamber) -70°C to +163°C
Vibration level: 1 to 60 GRMS, 3 Hz to 10 kHz with unloaded table

Compressed air: <20 SCFM maximum @ 689 kpa
Overall table weight: 90 kg (200 lbs)
Table base: 54 kg (120 lbs)

HALT/HASS

HALT/HASS chambers

HALT and HASS Time Compressor® chambers provide extreme temperature & vibration capabilities used during the product design and manufacturing cycles to compress the time normally required to identify design and process weaknesses.  HALT techniques are important in uncovering many of the weak links inherent to the design and fabrication process of a new product. HASS techniques are incorporated during the production phase to fing manufacturing process defects that could cause product failures in the field.

AGREE chambers

Cámaras AGREE

AV(H) MODEL
Capacity: 14 to 144 cu. ft. (397L to 4,078L)
Custom Sizes are available
Temperature ranges:

Single Stage: -34°C to +190°C (-30°F to +375°F)

Tundra® Range: -45°C to +190°C (-50°F to +375°F)

Tundra® II Range: -50°C to +190°C (-58°F to +375°F)

Cascade: -70°C to +190°C (-94°F to +375°F)

Optional Humidity range 10% to 95% RH

COMMERCIAL VIBRATION CHAMBER

cámaras comerciales de vibración


CV(H) Model
Capacity: 8 to 64 cu. ft. (230L to 1810L)
Custom sizes are available.

Temperature range:

Single Stage: -34°C to +190°C (-30°F to +375°F)

Tundra®: -45°C to +190°C (-50°F to +375°F)

Tundra® II: -50°C to +190°C (-58°F to +375°F)

Cascade: -70°C to +190°C (-94°F to +375°F)

Optional humidity range10% to 95% RH

ALTITUDE CHAMBERS

Model CA(H)

Capacity:

8, 16, 32, or 64 cu. ft. (230L, 450, 900L, o 1810L)
Custom sizes available

Temperature range:

  • Single Stage: -34°C a +190°C (-30°F a +375°F)

  • Tundra®: -45°C a +190°C (-50°F a +375°F)

  • Tundra® II: -50°C a +190°C (-58°F a +375°F)

  • Cascade: -70°C a +190°C (-94°F a +375°F)

Humidity range (Optional)

  • 10% a 95% RH

Altitude range:

  • 100,000 FT (8.2 Torr) Default

  • 175,000 FT (.37 Torr) Optional

ADVANTAGES

Testing with CSZ chambers provides the following benefits:

  • Includes the largest selection of standard features, starter DVD and the best warranty in the industry.

  • Spare parts and maintenance services.

  • Spare parts in stock.

  • Energy efficient cooling design. 

  • Its versatile design allows fot a full list of options to meet your specific requirements.

  • Best delivery time on the market.

  • Ensures product quality and reliability.

  • Reduce cost.

  • Increases profitability.

  • Exclusive Tundra® cooling system.